Cerbere

Gamma and X-ray monitoring beacon

This device is designed to measured gamma ambient dose equivalent rate. It replaces and improves the Alban beacon. The Cerbere beacon allows to monitor areas thanks to its remote wired SI-GAM probe, and can accordingly control the safety equipments (door, light, ...).

  • Compatible with SI-GAM smart probes range
  • Visual and sound alarms
  • Easy-to-use and user-friendly interface
  • Configurable On–Off-control outputs
  • Remote start
  • Suitable for fixed or mobile station

Documentation

Technical characteristics

Detection characteristics

  • Type: Gamma and X-ray monitoring beacon with detection probe. The detection characteristics depend ont the probe used.

Alarm characteristics

  • Threshold: Set by the user (the range of values depends on the probe)
  • Sound: Buzzer > 85 dBA at 30 centimeters
  • Visual: 1 orange flashing warning light

Electrical characteristics

  • Charge: 15 V / 2.4 A DC voltage (provided)
  • Battery use
  • Battery life without alarm: 20 hours
  • Battery life in alarm mode: 14 hours

Connectivity

Relay:

  • 3 relay outputs with 3 poles COM / NO / NC
  • 4 configurable switching states: Failure or Alarm / Operational / Failure / Alarm

Switch power:

  • 60 VA with 24 V max - on resistive charge
  • 40 W with 48 V DC

Remote start:

  • One 0 - 24 V logic digital input line

Mechanical and environmental characteristics

  • Dimensions: Beacon 570 x 260 x 160 mm - Probe 150 x Ø30 mm
  • Weight: 7.0 kg
  • IP code: Beacon IP2X - Probe IP67

Regulatory compliance

  • Compliance: IEC 60532

144H